Showing posts with label ductless Fume Hoods. Show all posts
Showing posts with label ductless Fume Hoods. Show all posts

Thursday, December 21, 2023

The Portable Fume Hood: Enhancing Safety and Flexibility in Laboratory Environments

 


Laboratory work demands precision, caution, and a commitment to safety. In pursuit of these goals, Cleatech, LLC offers an innovative solution: the Portable Fume Hood. Designed to address the evolving needs of modern laboratories, this portable hood provides a versatile and reliable containment system for various experiments and processes.

Versatility Redefined

 One of the key advantages of the Portable Fume Hood lies in its adaptability. Unlike traditional fixed fume hoods, this portable option offers flexibility in placement and usage. Its compact design allows for easy mobility, enabling researchers to perform experiments in various locations within the laboratory or even outside it, without compromising safety standards. This adaptability fosters an environment conducive to innovation and exploration.

Efficient Containment and Protection

The primary function of any fume hood is to contain hazardous substances and protect laboratory personnel. The Portable Fume Hood excels in this aspect by integrating advanced containment features while maintaining user-friendly accessibility. Equipped with high-quality materials and an effective ventilation system, it ensures the safe handling of chemicals, preventing exposure and minimizing risks.

Space Optimization

Space constraints in laboratories can hinder workflow and experimentation. The portable nature of Cleatech’s Fume Hood offers a practical solution to this challenge. Its compact size allows it to fit into smaller spaces while still providing a controlled environment for various procedures. This optimization of space enhances productivity and maximizes the utility of laboratory areas.

Enhanced Research Capabilities

In research environments, the ability to adapt swiftly to new requirements is invaluable. The Portable Fume Hood empowers researchers by offering a solution that aligns with their dynamic needs. Whether it's a change in experiment location or a sudden need for additional containment measures, this hood provides a swift and effective response, allowing scientists to focus on their work with confidence.

Eco-Friendly Design

Cleatech’s commitment to sustainability is evident in the design of the Portable Fume Hood. By incorporating energy-efficient components and materials that are eco-friendly, this hood minimizes its environmental footprint without compromising on performance. It stands as a testament to responsible innovation in laboratory equipment.

Conclusion

 The Portable Fume Hood from Cleatech LLC, redefines safety, adaptability, and efficiency in laboratory environments. Its portable design, efficient containment capabilities, space optimization, and commitment to sustainability make it an indispensable tool for modern researchers. Embrace the future of laboratory safety and productivity with this innovative solution.

Ready to elevate your laboratory safety and efficiency? Explore Cleatech’s Portable Fume Hood today and experience the versatility and reliability that redefine laboratory operations. Take a step towards a safer and more flexible research environment. Join the revolution in laboratory containment solutions – discover the Portable Fume Hood by Cleatech now!

Tuesday, April 26, 2022

Key Benefits Of Ductless Fume Hoods

The U.S. holds over 45% of the global pharmaceutical market. Our dominance of scientific and medical fields has allowed us to raise the bar when it comes to the development and circulation of life-saving and life-changing medications. Before these medicines can be offered to the general public, however, they must undergo a grueling testing period; clean room standards must be met to ensure that they aren’t tainted or contaminated.

Laboratory Fume Hoods

From GMP storage conditions to GMP quality control, there are a number of steps and tools that play a major role in this sterile environment.

Let’s take a look at some of the benefits that ductless fume hoods in particular offer.

Environmentally Friendly: Ductless fume hoods are designed to isolate and trap chemical vapors, thereby preventing their release into the outside environment. Because these chemicals can cause ecological harm, this type of fume hood is considered to be more environmentally friendly than others.

Versatile: There are many different kinds of fume hoods for many different applications. Ductless hoods each have their own filtration system based on their specific application; carbon filters are often used to capture vapors, organic solvents, acids, and even mercury and formaldehyde. For added air purity, HEPA filters can be installed.

Easy To Install: Ductless hoods are self-contained and don’t require venting to the outside. In fact, many units are portable and can be moved around with little difficulty — no filter changes necessary. The set up, operation, and filter maintenance of ductless fume hoods are all very straightforward and easy to comprehend.

Energy Efficient: When clean, filtered air is returned to the room, the need to move air in is eliminated. As a result, the facility’s HVAC system does not have to work as hard.

Cost Effective: As their name suggests, fume hoods don’t require ducts. This means that HVAC and construction costs can be completely eliminated from the equation.

Fume hoods are a necessary part of the laboratory environment. Ductless fume hoods provide several unique advantages that put them ahead of the ducted variety. As long as you’re fully committed to maintaining your clean room standards, however, either option will do the trick.

Tuesday, June 23, 2020

Use the Laboratory fume hood effectively

An essential role has played by fume hoods and keeping technicians safe from all sorts of harmful chemicals by offering the best ventilation system. These bench fume hoods are best at controlling and absorbing any kind of substance that may hazardous for anyone such as fumes, gasses, dust, vapors, and aerosol. When a chemical reaction occurs then it will act as a barrier within the lab.



On the flip side, technicians as well as workers need to use it in a way that can work effectively and accurately to let get the whole benefits related to protective measures.
Thus, we are providing to make sure that laboratory benchtop fume hood provides utmost protection against toxic fumes, dangerous reactions as well as chemical spills.

Minimize Air Disturbances

The effectiveness of a fume hood can decrease airflow disturbances. That is the reason that it is important to find out the suitable size for the hood is necessary for maintaining the good order of working. After a fume hood is installed, then place it where it can avoid crosscurrents. Many things can lead to result in crosscurrents such as pedestrian traffic, windows, exterior fans, the opening and closing of doors, and windows.

To make sure the maximum containment, it starts avoiding the area of high-traffic so the worker starts moving around the hood. An air disturbance may create by avoiding the quick movement from in and out of the hood.

Make sure that Exhaust is working properly

Before beginning their work in the lab, the technicians make sure that the exhaust is working properly. The main job of a benchtop fume hoods is exhausting fumes, so if this part is not working properly then there may be some issues in the whole operation.



Check the baffles entirely when ensuring that the exhaust is working. Such parts of the ventilation system are movable partitions that create openings in the back of the hood. It is helpful to keep the airflow uniform that increases efficiency. Check out any obstructions that may hamper the airflow.

Airflow monitor is also included in the hood and regularly check the status. Making sure that it is properly functioning will enable you to better examine any suspected changes in the process of airflow.

Practice Good Procedures

In equipment that has an amazing feature of exceptional hood design only provides high efficiency if the equipment is used effectively. The key is to do proper operating procedures. A set of instructions as well as procedures by the manufacturers will come along with each kind of fume hood. On the flip side, some instances of good lab benchtop fume hood procedures comprising the following:
  • If there is any large apparatus on the inner area of the hood, then put blocks under the equipment so that air can flow below it.
  • Keep the hood closed if you are not working in the hood or setting up any apparatus.
  • Whenever it is possible to keep the hood sash closed to increase the performance. If there is any power outage happens, then lesser the hood sash to within an inch. So, it creates a chimney effect to let the airflow.
  • You need to be aware of while dealing with some materials such as paper products, aluminum foil, and chemical wipes. These are light in weight and can easily suck into the hood and may impede airflow.
  • Utilize the sliding sash barrier if you are using a benchtop fume hood. This one is good for protection and allows you to keep your face aside from the work area.
Prioritize Housekeeping As Well As Maintenance

It is important to have proper housekeeping as well as up-to-date maintenance that is necessary to make sure that the lab fume hood is working properly and providing high performance. Here are some housekeeping and maintenance procedures that you need to implement involve:
  • Never store items like chemicals in the hood. They can block the airflow and also interfere with containment too. It is recommended to keep fifty percent of the workplace clear all the time.
  • Store the harmful chemicals in the approved safety cabinets. If there is a need for harmful chemicals, then take a small portion of it in the hood. Bio-safety cabinets are designed with a motive of proffering protection against biological material exposure and also serve various functions. It is vital to use the right cabinet for a definite chemical or biological material.
  • You need to check the fume filters if you are using the ductless fume hoods to ensure that they are clean or require to be replaced. To remove hazardous fumes as well as particles from the lab, these clean and carbon filters play a significant role.
Do you want to use a benchtop fume hood?

If you want to use such a benchtop fume hood, then make sure to keep all these things in mind and use it effectively and correctly.

Tuesday, January 7, 2020

What To Look For When Purchasing A Benchtop Ductless Fume Hoods?


Ductless fume hoods are described by multiple names like filtered fume hoods, or carbon-filtered enclosures. Ductless Fume Hoods are self-contained and filtered laboratory enclosures that eliminates dangerous fumes, vapors as well as particles from the laboratory.

Not like conventional fume hoods, investment prices are very cheap plus no ductwork is needed. Hence, countless people think choosing one is a slam-dunk when they first discover them.

There are few crucial things to analyze before reaching the final choice to buy a ductless fume hood. Consider these aspects into careful thought to be sure that a ductless fume hood is the correct decision for the Laboratory Supplies the applications:

1. Is the common application suitable for a ductless fume hood?

Countless different classes of ductless as well as the filtered fume hoods few hoods still restrict application that can be implemented in them. Few ductless fume hoods should only be utilized light-duty instead of process explicit fume hoods. Additionally filtered fume hoods can be utilized for a broad range of chemicals, however, keep in thought that more extensive chemical amounts will ever reduce filter life. 

This indicates that:

   ·        A restricted number of complex chemicals should be applied.
   ·        No excessive heating should be taken out in the hood.
 ·  Unostentatious chemical amounts should be accepted, about 500 mls or less by chemical.
   ·        Mediocre chemical display times should be managed.

2. Will the chemicals included in the application be adequately filtered with the available carbon filters?

Typically, ductless hoods will be equipped with chemical explicit filters. Explicit filter kinds enhance chemical trapping capability for complex chemical groups; but, few chemicals cannot be securely filtered or are not filtered efficiently sufficient to enable ductless hoods to be a financially viable alternative.

3. How frequently will you have to substitute the filters?

Although you won't have the added cost of tube work downloading and wiring together with a standard fume hood you want to consider how often you want to remove your filters, and the maintenance costs associated with that, to add your total yearly filter costs.

Filter lifespans can end from a few months up to two years. You will want to search out how long the expected filter lifespan is for your application so the weigh that against the cost to establish a standard fume hood. It also considers the energy cost of running a standard fume hood which totally replaces tempered air from the laboratory and taxing the HVAC system.

4. How do the pros as well as cons of utilizing a ductless fume hood stability out for you?

If you possess decided that a ductless fume hood is most apparent suitable for the application, the ultimate thing to perform is to decide how the benefits of a ductless fume hood persist up against its disadvantages, plus how both adjust with the organization's overall purposes. 

Conclusion 

These four things are very important to look For When Purchasing a Benchtop Ductless Fume Hoods, before buying benchtop ductless fume hoods these four points will help you.

Wednesday, September 11, 2019

Explain The Different Types Of Fume Hoods


Introduction
Fume Hoods are devices to protect the users in a lab from the dangerous toxic vapors and fumes. Certified filters are used to filter out the harmful fumes and provide protection to the user. The box like unit has a tall base. They are mostly used in laboratories. Its main components include sash, air foil, work surface, baffles, exhaust, and hood body.

Different fume hoods


Types of fume hoods available in the market include Canopy Fume, Chemical Fume Hood, ADA Fume Hood, Ductless Fume Hood, Extractor Arm Fume Hood, Biosafety Cabinet/ Hood, Variable Air Volume Fume Hood, Perchloric Acid Fume Hood, Portable Fume Hoods, Polypropylene Fume Hood, Walk In Fume Hood, and Radiosotope Fume Hood.

Chemical Fume Hood

Chemical fume hoods are used in the labs to protect the users by handling the harmful chemicals. It reduces the exposure to dangerous vapors and chemicals in a lab. It is developed using a good quality steel.

Ductless Fume Hood

Carbon Filters are used in the ductless Fume Hoods to eliminate vapors and fumes in a laboratory. Carbon filters are environment friendly and advanced. It eliminates the harmful fumes and provides a clean air to the lab. They are cost effective and energy efficient. It also comes with an electronic monitoring system to ensure efficient operation of the carbon filter.

Canopy Fume Hoods

Canopy Fume Hood is used for non-toxic materials. It eliminates odors and heat steam. It is ideal for use over the ovens.

ADA Fume Hood

This ADA compliant fume hood is developed to provide a safe work environment for the technicians. It is engineered perfectly to meet the safety needs by properly aligning digital air flow monitors, switches, lights, and epoxy coated steel for the exterior. It facilitates hand operation.

Low Air Flow Fume Hood

It is developed to operate at reduced rate when compared to the standard unit. It takes less space in a lab. It saves 40% of electricity bill.

Extractor Arm Fume Hood

It is a local exhaust ventilation system. It eliminates local air streams, odors and fumes. Its size varies from 2 inches to 4 inches. The extractor arm fume hoods can be fitted on a wall, bench or a ceiling. It can be customized to suit your lab requirement.

Biosafety Hood

Biosafety fume hoods and cabinets are ideal for labs where communicable diseases are handled. The technicians can safely work with materials that are contaminated with the pathogens.

Variable Air Volume Fume Hood

The volume of air that is exhausted can be controlled in this fume hood. It maintains a constant velocity. It can be used with exhaust controller systems of other producers. It has a sash to provide a clear view to the user. It provides visual clarity with interior lighting.

Perchloric Acid Fume Hood

The steel device is developed to work with perchloric acid. It helps to prevent the formation of perchlorate salt. It can be customized to meet your lab needs.

Those searching for fume hoods can choose the right fume hood for their lab needs and get protection in a lab.